PT. BEST INSTRUMENT INDONESIA

ETCR Lightning Protection Standard Resistor

EM3900 Lightning Protection Specialized Standard Resistor

EM3900 Lightning Protection Specialized Standard Resistor
Product Series : Lightning Protection Standard Resistor
Main FeaturesUsed for calibrating instruments such as earth resistance testers and equipotential testers.
Scales: 1mΩ, 10mΩ, 100mΩ, 1Ω, 10Ω, 100Ω, 1kΩ, 100kΩ (8 ranges)
Range: 10⁻³ ~ 10⁵Ω
Accuracy: 0.05%
Power: 1/2W
Resistor: High-precision wirewound resistor

The EM3900 Lightning Protection Specialized Standard Resistor consists of nine 1/2W high-precision wirewound resistors. Calibration allows for direct switching and testing without changing test leads. Its stable performance and robust construction make calibration test particularly convenient. The high-precision wirewound resistors feature a maximum accuracy of 0.05%. Available resistance values include 1mΩ, 10mΩ, 100mΩ, 1Ω, 10Ω, 100Ω, 1kΩ, and 100kΩ, fully meeting the 10⁻³ ~ 10⁵Ω range specified in National Meteorological Administration Order No. 38, “Administrative Measures for the Qualification and Inspection of Lightning Protection Devices.” This standard resistor is primarily used for calibrating instruments such as earth resistance testers and equipotential testers. It is widely used in building quality inspection stations, supervision companies, construction companies, lightning protection companies, and power companies.
ETCRMETER is a high-end brand of ETCR. All products are manufactured by ETCR, which also provides technical support and after-sales service.

Product Features
1. Made of high-precision winding resistors, it has stable performance and strong structure, and is particularly convenient for calibration.
2. Fully meetss the national weather service order “Lightning Protection Device Detection Qualification Management Approach” specified in the range of 10-3 ~ 105 Ω.
3. Eight output levels: 1mΩ, 10mΩ, 100mΩ, 1Ω, 10Ω, 100Ω, 1kΩ, 100kΩ.
EM3900 (7).jpg EM3900 (8).jpg

Technical Parameters

Specification NameParameters Description
FunctionsUsed for calibrating instruments such as earth resistance testers and equipotential testers
Wiring MethodFour-wire method
Range & Accuracy0.001Ω; 2%
0.01Ω; 0.5%
0.1Ω; 0.2%
1.0Ω; 0.2%
10Ω; 0.05%
100Ω; 0.05%
1kΩ; 0.05%
10kΩ; 0.05%
100kΩ; 0.05%
Power1 / 2W
Temperature Coefficient± 25ppm
Test LineRed(0.5m)*2pcs,Black(0.5m)*2pcs
Dimensions173mm x 125mm x 70mm
WeightHost: approx. 345g;
Total weight: approx. 1.32kg (include accessories)
Insulation ResistanceAbove 10MΩ (500V between the circuit and the housing)
Withstand VoltageAC 3700V/rms (between circuit and housing)
Working Temperature & Humidity-10℃~40℃; below 70%RH
Storage Temperature & Humidity-20℃~60℃; below 80%RH
Safety StandardIEC61010-1, CAT Ⅲ600V, pollution level, JJG166-1993 {DC resistor verification procedures}

Model Comparison

Commonly Used Instruments in Lightning Protection Industry

Product NameModelMain Parameters
Clamp-on Earth Resistance TesterEM2000+Measuring Range: 0 ~ 1000Ω, Resolution: 0.01Ω
Digital Earth Resistance TesterEM3040Test current: > 20mA (sine wave), Resolution: 0.01Ω
Earth Grid TesterEM3300BTest current: > 3A, Resolution: 0.001 ~ 99.999Ω, Selectable frequency
Soil Resistivity TesterEM3040B4-wire measurement, Test current: > 20mA (sine wave), Resolution: 0.01Ω
Equipotential TesterEM3700Test current: > 1A, 4-wire test, Resolution: 0.001Ω, Equipped with large-capacity lithium battery
Loop Resistance TesterEM2150Resistance measurement resolution: 0.001Ω, Current measurement resolution: 1uA
Lightning Protection Component TesterEM3800Test component: MOV, Equipped with large-capacity lithium battery
Insulation Resistance TesterEM3460A0 ~ 1000MΩ
Surface Resistance TesterEM3420Measuring range: 10³ ~ 10¹⁰Ω
Digital MultimeterEM5930Voltage, current, resistance measurement, Resolution: 3.5 digits
Standard ResistorEM390010⁻³ ~ 10⁵Ω, Power: 1/2w, Wire-wound type